摘要: |
[摘要] 目的 探讨在腹腔镜阑尾切除术(LA)中运用普通丝线结扎阑尾动脉及阑尾根部的安全性及可靠性。方法 对2008-12~2009-10施行无钛夹LA的29例患者的临床资料进行回顾性分析。结果 所有患者均顺利完成LA,无中转开腹。平均手术时间39.2 min,平均住院4.5 d。无肠粘连、肠梗阻及切口疝等并发症的出现。结论 运用普通丝线结扎阑尾动脉及根部,对人体无损伤,安全、可靠。 |
关键词: 腹腔镜 阑尾切除术 丝线 钛夹 |
DOI:10.3969/j.issn.1674-3806.2010.03.15 |
分类号:R 656.8 |
基金项目: |
|
Laparoscopic appendectomy without using titanium clips |
HUANG Yong-fa,HUANG Jia-cong,TANG Tao
|
Department of Surgery, Fangchen District People′s Hospital,Fangchenggang Guangxi 538021,China
|
Abstract: |
[Abstract] Objective To investigate the safety and reliability of applying common silk suture to ligate appendicular artery and appendix root in laparoscopic appendectomy(LA).Methods The clinical data of 29 patients who were treated with LA without using titanium clips in our hospital were analyzed from December 2008 to October 2009.Results LA in all patients were successfully completed, without the conversion to laparotomy. The average operation time was 39.2 min and the average length of stay was 4.5 d. No intestinal adhesion, intestinal obstruction, incisional hernia and other complications occurred.Conclusion Applying common silk suture to ligate appendicular artery and appendix root has not injury to human body,and is safe and reliable. |
Key words: Laparoscopy Appendectomy Silk suture Titanium clip |